![]() What to do if Compatibility tab 'Change high DPI setting' is not available and Blue Prism tool view was blurred? (settings as on screenshot). ![]() The latest Blue Prism Group stock prices, stock quotes, news, and BPRMF history. Trainer will share Blue Prism certification. In the pop-up, check the option Override high DPI scaling behavior. Shareholder percentage totals can add to more than 100 because some holders are included in the free float. BluePrism Training program comprises a combination of configuring a Blue Prism Process Solution, discussions. On the Compatibility tab select Change high DPI settings The timeout period elapsed prior to completion of the operation or the server is not responding. prism, they are respectively : - Yellow Green 1-627749 dark line B 1.629681 C Red Orange. I have my flow built, but I am getting: Execution Timeout Expired. Thank you for sugestion, but as you see on the screen above, it not exist this: I am attempting to run a delete SQL query on a DB in Blue Prism. That will drastically increase the amount of addressable memory available to your processes. Important : When your process relies on attaching to an instance of the Chrome, Firefox, or Edge that BPE did not initially launch via the Application Modeller, then enabling the setting above will allow your existing process to continue running.Subject: Blue prism Tool view was blurred - continued Alternatively, Blue Prism v7.2, which is upcoming, will be the first release of the product where the client application will be a true 64-bit application. As you have the value for Role from the WorkQ and want to compare it against a collection derived from an XL, Id do the following: Filter the collection using the WorkQ Role value to see if that value exists and has the correct name. If you are in latest blue prism i believe you can expose the work queue as API and build connector in power automate cloud and schedule the flow to poll the response from API and perform the next steps in the. The Blue Prism codebase for v7.0 likely does not contain the necessary pre-requisites to support this new functionality that was introduced for the v7.1 codebase. Blue Prism Group plc is a United Kingdom-based company that provides intelligent automation solutions for enterprises to transform their work. As other members mentioned the easiest and straight forward way is sending an email or triggering by some event in power automate cloud. Please keep in mind below scenario before you disable this setting. Hi Neeraj, Based on past product release history, its unlikely that BP Desktop functionality would be 'back-ported' to versions released prior to its initial availability. However the recent versions of BP uses a range of peripheral ports for this. Where all the communications between BP and browser was channelled through the port - 31924. This setting was provided for the older versions of BPE for browser automations. ![]() You can find it in the System > Settings: This resolved the attach issues for me especially when I run the process in debug mode and in Control room on the same machine. > Check if the use of fixed browser extension port(31924) checkbox is enabled and uncheck it if checked. For some server, even if the Extension is present, we are facing issue with "Attach" the target application. > Need to check your bot account access and group policies configured for controlling browser extensions. The Extension used to remove by itself from the Edge even after adding manually.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |